Turnkey Projects

Select the area you want to secure

Turnkey is essentially a fixed price contract. It means that the General Contractor/ Construction firm is officially obliged to conduct the entire operation from Design to Close-out – including subcontractors, materials, machinery and equipment – from within that fixed price.

Fire Pump Room

A fire pump is a part of a fire sprinkler, internal and external Hydrant system’s water supply and can be powered by electric, diesel pump, jockey pump. The pump intake is connected to the independent fire sump. The pump provides water flow at a higher pressure to the sprinkler system, risers and hose stand pipes.

Fire Hydrant System

In a building, a fire hydrant system is a safety measure or emergency equipment required in some buildings that comprises a series of components that when assembled together provide a source of water to extinguish.

A fire hydrant system is a water supply with a sufficient pressure and flow delivered through pipes throughout a building to strategically located network of fire hydrant landing valves for fire-fighting purposes.

In circumstances, Water from a reticulated fire hydrant system can also be shared with other safety
measures such as automatic fire sprinkler systems or fire hose reels.

Fire Sprinkler System

A fire sprinkler system is an active fire protection method, consisting of a water supply system, providing adequate pressure and flow rate to a water distribution piping system, onto which fire sprinklers are connected.
A fire sprinkler is the component of a fire sprinkler system that discharges water when the effects of a fire have been detected, such as when a predetermined temperature has been exceeded. Fire sprinklers are extensively used worldwide.

Gas Suppression System

i) CO2 Flooding Fire Suppression System

Carbon dioxide or CO 2 is a colorless, odorless, electrically non-conductive gas that is highly efficient as a fire suppression agent. Carbon Dioxide fire protection systems use intelligent, reliable and fast-acting control panels to quickly sense a fire before it can cause damage to property. Carbon dioxide gas has a high rate of expansion, which allows a CO2 fire protection system to work fast.

ii) FM200 Fire Suppression Systems (HFC227ea)

FM200 fire suppression is also known as HFC227ea. FM200 is a waterless fire protection system, it is discharged into the risk within 10 seconds and suppresses the fire immediately.
These gases are stored as a liquid, with nitrogen used to pressurize it. When released the FM200 has a chemical reaction with the fire and extinguishes it.

iii) NOVEC Fire Suppression Systems

It is used as gaseous fire suppression agent in scenarios where water-based fire suppression (for example, from a fire sprinkler) would be impractical or where it could damage expensive equipment or property, such as museums, server rooms, banks, clean rooms and hospitals.